ACHR News
search
Ask ACHR NEWS AI
cart
facebook twitter instagram linkedin youtube
  • Sign In
  • Subscribe
  • Sign Out
  • My Account
ACHR News
  • NEWS
    • Breaking News
    • New HVAC Products
    • Featured Products
    • Manufacturer Reports
    • HVAC Data
    • Legislation
    • ACHR NEWS Centennial
  • RESIDENTIAL
    • Air Conditioners
    • Furnaces
    • Residential Heat Pumps
    • Ductless
    • Residential IAQ
    • Testing, Monitoring, Tools
    • Components & Accessories
  • COMMERCIAL
    • Air Handlers
    • Rooftop Units
    • Chillers and Cooling Towers
    • Commercial Heat Pumps
    • Boilers and Hydronics
    • VRF/Ductless
    • Commercial IAQ
  • REFRIGERATION
    • Refrigerants
    • Refrigerant Regulations
    • Leak Management
  • CONTRACTOR PRO
    • Geothermal
    • Homeowner Study
    • VRF and VRV Ductless
    • Unitary Trends
  • EDUCATION
    • Training and Education
    • Business Management
    • Service and Maintenance
    • Continuing Education
    • Market Research >
      • HVAC Brand Awareness Report
      • VRV, VRF, VRVZ Report
      • Unitary Trends Report
      • Water Heat Professionals Report
    • Webinars
    • Sponsor Insights
    • eProducts Info
    • White Papers
  • EVENTS
    • HVAC Contractor Forum
    • Industry Events and Webinars
  • MEDIA
    • Videos
    • AHR Expo 2025 Videos
    • Podcasts >
      • ACHR News Podcast
      • HARDI Podcasts
      • AHR Expo Podcasts
      • ACCA Podcasts
    • Interactive Spotlights
    • Quizzes
    • eBooks
    • HVAC Talkback
  • HVAC GROUP
    • ACHR NEWS >
      • Current Issue
      • Digital Edition
      • Subscribe
    • Distribution Trends
    • SNIPS NEWS >
      • Join SNIPS NEWS
    • Engineered Systems News >
      • Join ES News
    • HVACR Directory
    • Contests
    • Newsletters
    • Contact
    • Advertise
    • My Account
HVAC Residential MarketHVAC Light Commercial MarketHVAC Commercial MarketRefrigeration

Troubleshooting a Compressor Burnout

Compressor burnouts are rare but knowing how to deal with them is essential

By Ron Rajecki
Burned Scroll

BURNT TO A CRISP: A scroll member (left) is blackened due to burned oil and winding insulation from a burnout. A scroll crankshaft (right) from a compressor that failed due to overheating. Photo courtesy of Danfoss

March 27, 2017

Compressor failure can be traced to a number of system issues, including high condensing pressures, refrigerant floodback, service or replacement issues, a loss of charge, liquid slugging, motor burnout, and more.

Compressor burnout is a very specific mode of failure that may be caused by high temperatures in the motor windings or discharge area of the compressor. High temperatures break down the motor winding insulation, which may cause a loss of electrical resistance and result in a short to the ground or even an open winding.

If the oil breaks down, it can no longer provide adequate lubrication, which may cause the bearings or pistons to seize.

When a compressor fails, a comprehensive “autopsy” is necessary to properly correct the issue.

“Getting a system up and running after a compressor burnout requires certain steps that, if done correctly, may be the difference between years of trouble-free operation or only a few months before the replacement compressor also fails and needs replacement,” said Jamie Kitchen, a trainer at Danfoss.

CAUSES AND CULPRITS

According to Kitchen, the main causes of burnout are insufficient cooling from the suction gas as well as compressor operation outside of its application envelope. High condensing pressures are a common culprit. Since the returning gas (suction) provides a large portion of the cooling for the compressor motor, if there is not enough of it coming back as a result of a loss of charge, or if the superheat value of the gas is too high, the motor will not have enough heat removed from it and will overheat. Common causes of high condensing pressure are undersized and/or dirty condensers, failure of the fan motor, incorrectly set or inoperable fan controls, or recirculation of the condenser leaving air. All of these should be checked during the startup and commissioning phase.

Kitchen offered five steps to follow when starting up and commissioning a system after a compressor burnout.

Looking for quick answers on air conditioning, heating and refrigeration topics? Try Ask ACHR NEWS, our new smart AI search tool. Ask ACHR NEWS →

“These steps will eliminate the vast majority of the reasons compressors fail, regardless of what did them in,” he said.

1) It is important to realize that not all burned out compressors are acidic. This is a holdover to the days when all refrigerants were chlorinated and compressors were charged with mineral oil. These systems could produce acid simply by overheating.

“With today’s hydrofluorocarbon [HFC] refrigerants and polyolester [POE] oils, it is impossible to produce acid without the presence of moisture,” Kitchen said. “Always verify that the oil is acidic by using the correct oil test kit before spending a lot of time and money treating the system as if it were acidic.”

2) Regardless whether or not the system is acidic, there will likely be burned oil, winding insulation, and possible other contaminates in the system. Flush the system using a flush approved by the manufacturer while making sure to remove the TXV so that contaminates are not flushed into it. Ensure the evaporator and condenser are flushed so that the flushing agent comes out clean when done. Kitchen advised that this process should be repeated for all other refrigerant lines. This will remove residual oil that could be holding contaminates, which, if left in the system, can come back to plug up the unit and contaminate the oil in the new compressor.

3) If the compressor was part of a parallel compressor group, and therefore shares the same suction and oil equalization with other units, be sure to inspect the oil in the other compressors and look for discoloration. Discoloration can mean that burned oil may have made its way into the other compressors or that they were operating too hot. If this is the case, then the oil in the other compressors will also need to be replaced.

“If the oil in the failed compressor is acidic, the oil in the other compressors will be, as well; however, this does not automatically mean they will need to be replaced,” Kitchen explained. “If the winding insulation checks out fine, replace the oil with new oil. The system flush will make sure that all contaminated oil is eliminated from the rest of the system.”

4) According to Kitchen, if the system was not acidic, then, once the system has been flushed clean, a good liquid line drier with activated alumina and molecular sieve desiccant will work fine. However, if the system was acidic, then the further steps of installing a suction line and acid removing drier are required. This is especially true if the refrigerant in the system is chlorinated as the type of acid produced by it can adhere to surfaces inside and take a while to fully come out. Plus, the chlorinated refrigerant will act as a catalyst to further acidify the new oil.

“Remember that suction driers are not install-and-forget devices. If residual acid is present in the system, it will cause a pressure drop in the drier, which needs to be monitored,” he said. “If a pressure drop occurs, a new drier will need to be installed. This will need to be continued until the plugging and resulting pressure drop stops.”

5) Finally, it is paramount to remember that the whole purpose of commissioning is to catch anything that may impact the proper operation of the system and its components. Do not be distracted by the fact that the system burned out or is acidic and miss the very issue that resulted in the failure in the first place. What if poor voltage to the compressor caused it to overheat, resulting in winding or oil failure? How do you know until you check for it? Unless it is corrected, the new compressor will soon fail, as well. This also goes for poor oil return or short cycling. Refrigerant leaks and improper evacuation can also result in compressor burnout. In other words, following proper installation and startup procedures is crucial.

“When done properly and when combined with the special considerations for a burnout discussed in this article, proper installation and startup procedures can help ensure that a compressor will operate properly for years to come,” Kitchen said.

FROM THE FIELD

Randy Hamilton, technical advisor and comfort consultant for GAC Services, Gaithersburg, Maryland, agrees that determining the cause of a compressor burnout is an essential part of any post-burnout cleanup.

“If you just replace the compressor, weigh the charge in, and then turn around and leave, you’ll never be sure what caused the problem,” he said. “We always want to get an idea what created the compressor failure in the first place.”

Hamilton said GAC Services performs a duct airflow calculation to ensure the system is being supplied with the proper amount of return air. Proper airflow can reduce the stress on a compressor and prevent slugging. The duct calculation can be done while the vacuum pump is running, he noted.

GAC’s technicians also spend a little extra time analyzing the system’s components.

“We might do a stress test of the TXV and put the sensing bulb in some hot or cold water to make sure it’s performing properly,” Hamilton said. “Then, once we fire up the new compressor, we do a complete system analysis to make sure everything’s performing correctly.”

Finally, Hamilton advised technicians who are dealing with a system cleanup to either pull and drain or replace the accumulator tank.

“There’s usually a lot of old oil from the compressor failure in the accumulator,” Hamilton said. “Even if you evacuate the system to remove the moisture and contamination, you can still have some of that old oil in the accumulator and end up sending contaminants through the system when you start-up the system.”

Changing the accumulator not only eliminates the potential for contaminants to be reintroduced into the clean system, it can also save time, especially if it’s done at the beginning of the process.

“If it’s winter and you’ve got some extra refrigerant in an accumulator tank, it can be a real drag to evacuate it all,” Hamilton said. “You might be there for hours. Sometimes, just replacing the accumulator at the beginning of the process allows you to reduce your vacuum time so much that it pays for the cost of the new tank.”

ADDITIONAL TIPS

Kelsey Poe, director of marketing and sales, CMP Corp., offered three additional helpful tips for cleaning a system after a compressor burnout:

• Inspect all valves, including expansion valves, solenoid valves, check valves, and reversing valves. Clean and replace them if necessary;

• Remove and replace the filter driers already installed in the system. For system-cleaning purposes, install an appropriately sized filter drier in the suction line and an oversized filter drier in the liquid line. After all cleaning procedures are finished, install a properly sized filter drier in the liquid line and remove the suction line filter and replace with a permanent filter; and

• Take an oil sample from the replacement compressor just after installation. Put that in a small glass container and set it to the side. After your replacement unit has operated for 48 hours, check the color and smell of the oil. Compare it to your original sample. Look for discolored or acrid-smelling oil and use a moisture indicator to see what the moisture content is in your system. If you find acid or a high moisture content, change the filter driers again. Allow the system to operate for two more days and re-check. Repeat this process until the oil is the same color as your original sample and free of any odor. 



STEP BY STEP: REPLACING AN HVACR COMPRESSOR

Darrel Yashinsky, president, Air Quality Dunrite, Concord, Ontario, Canada, shared the steps his company recently took when replacing a customer’s burned out compressor:

We recently helped a customer who had experienced a compressor burnout. We discussed options regarding repair or replacement. Because of the complexity of the system and the cost for a new unit, the customer opted for a compressor replacement.

This system is used for pool heating and rejects heat to the pool. When the pool water temperature is satisfied, the unit rejects heat to an in-ground loop.

To ensure as long a life as possible, we tested the compressor and found it grounded out. A grounded compressor does not indicate a burnout but is a strong indication of a significant problem. We performed an acid test on the refrigerant and found it to be slightly acidic. We elected to clean up the system using a suction filter dry-out kit. We then power-washed the dirty evaporator coil and checked water flow through both condenser loops. To prevent future problems, we also ran descaler through the condenser loops.

We pumped out the refrigerant and installed a catch-all filter-drier shell with a burnout core and then installed an access valve on the gauge port to measure pressure drop across the drier. Next, we installed an oversized liquid-line drier.

After all that was done, we replaced the compressor. We then pumped the system down for 24 hours to pull a deep vacuum before recharging the system with virgin refrigerant per the manufacturer’s recommendation. We then checked the superheat.

The next step was to let the unit run for 24 hours and recheck for acid and pressure drop across the new suction drier core. After that, we ran the unit for 48 more hours and performed another acid check. No acid was present, so we replaced the acid core with a standard core. However, to be safe, we wanted to continue to monitor the system, so we returned after one week to test for acid again. We found no acid or significant pressure drop across suction filter, so we removed the filter and installed a felt element in the core.

The system has been running well for the past 90 days. We will recheck it during regularly scheduled maintenance. 


Publication date: 3/27/2017

Want more HVAC industry news and information? Join The NEWS on Facebook, Twitter, and LinkedIn today!

KEYWORDS: compressor troubleshooting

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Ron Rajecki is the marketing content specialist for Aquatherm North America. 

Recommended Content

JOIN TODAY
To unlock your recommendations.

Already have an account? Sign In

  • HVAC-enrollment

    The Trades Are Back: HVACR Programs See Nearly 30% Enrollment Spike

    A new wave of future technicians is entering the pipeline.  
    News
    By: Matt Jachman
  • 2025 Top 40 Under 40

    2025 Top 40 Under 40 HVACR Professionals List

    The 11th annual Top 40 Under 40 list highlights those...
    HVAC Contracting
    By: Hannah Belloli-Oster
  • LG Ductless Mini-Split Systems

    The 9 Types of Heat Pumps

    As the U.S. moves toward electrification, heat pumps are...
    Heat Pumps
    By: Joanna R. Turpin
Subscription Center
  • Create an Account
  • Start a Subscription
  • Manage My Account
  • Sign Up for Newsletters
  • Visit Customer Service
  • Update Preferences

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to The News audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The News or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • Piggy Bank
    Sponsored byWatercress Financial

    Energy Prices, Inflation, and HVAC: What Today’s Homeowners Care About

  • Refrigerated Food
    Sponsored bySolstice Advanced Materials

    R-455A Refrigeration: A Cold Storage Solution for the Future

  • Airex Rooftop Units
    Sponsored byAirex Manufacturing Inc

    Consolidating Roof Penetrations: A Growing Trend in Multifamily HVAC Design

Popular Stories

Outdoor-condensing-units.jpg

EPA Removes R-410A Installation Deadline

HVAC-Price-Increase-graphic

HVAC Price Increase List: June 2026

Trump-Section-232.jpg

Trump Reduces Section 232 Tariffs on HVAC Equipment to 15%

ACHR NEWS Editor Chris Gray Presenting HVAC Minute 5-18-2026

HVAC Manufacturers Fight Pricing Lawsuits

R410A-Refrigerant-Cylinder.jpg

Refrigerant Recovery is a Revenue Opportunity

View The ACHR NEWS
Centennial Anniversary Timeline

The ACHR News Timeline Chart
Submit a Letter
Submit a letter to our editors.

Events

November 6, 2025

Next-Gen Data Center Cooling: HVAC Innovation and Real-World Solutions

On Demand As AI workloads and high-density computing push traditional cooling methods to their limits, the data center industry is accelerating the adoption of next-generation HVAC technologies.

June 9, 2026

Before You Go All In on AI: Set Up Your Business to Actually Win

In this webinar, we'll walk you through exactly what to get in place before you add AI to your business. You'll leave with a clear picture of where you stand today and a practical action plan to set yourself up for real results.

View All Submit An Event

Poll

Summer Staff

Are you fully staffed for the summer season?
View Results Poll Archive

Products

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

BNI Mechanical/Electrical Square Foot Costbook, 2026 Edition

See More Products
A2L Refrigerants - Free Webinar - May 21, 2026

Related Articles

  • HVAC Tech Turned Wholesaler Salvages Compressor Burnout

    See More
  • HVAC Tech Turned Wholesaler Salvages Compressor Burnout

    See More
  • AugTrouble-ACHR-NEWS

    Troubleshooting Scenario: A Compressor Diagnosis Follow-Up

    See More

Related Products

See More Products
  • Troubleshooting Tips for Servicing Refrigeration Systems

  • HVAC/R Electrical Troubleshooting: Deciding where to begin DVD

  • HVAC/R Electrical Troubleshooting: Component Testing Training Kit

See More Products

Related Directories

  • Carlyle Compressor

    Count on Carlyle. Carlyle compressors can be found around the world - from the first nuclear sub to your grocer's freezer to entire bus fleets.
×

Sign Up. Stay Informed.

The #1 trusted source for the HVACR industry since 1926

SUBSCRIBE
  • RESOURCES
    • Advertise
    • Contact Us
    • Advisory Board
    • Classifieds
    • Submit a Letter
    • Directories
    • Store
  • ACCOUNT CENTER
    • Create an Account
    • Start a Subscription
    • Manage My Account
    • Sign Up for Newsletters
    • Visit Customer Service
    • Update Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing